T5 Series Features
T5 series self-hold thermal cut-outs are similar structure as auto-reset types except they are fitted with a PTC heating element. Once T5 reaches its open temp., the contacts open and the load current then passes through this internal PTC heating element. The heat thus generated stops the bimetal disc from auto-resetting and protects the appliance from over-heating. The thermal cutout will remain in an open-circuit condition until the applied power is switched off and the internal PTC is allowed to cool down. The T5 will then auto-reset and so re-make the electrical circuit.
Reset type
Manually disconnecting the power supply to reset the thermostat, then re-plug the power supply.
single pole single throw(SPST)
Electrical rating(Resistive load)
UL :125VAC~10A/16A;
TUV:250VAC~10A/16A;
CQC:250VAC~10A/16A;
30 K life cycles
Operating temperature range
Ceramic housing : 45 - 200℃ (113℉ to 392℉);
Switch type
Normally closed (NC): contacts open on temperature rise;
Dielectric strength & Insulation
No less than 1,500VAC/1min or 1,800VAC/1Sec.;
No less than 500VDC/100MΩ for insulation resistance;
Application
Room radiator etc..